What we do on a maintenance visit
- Flush sediment from the tank bottom until it runs clear
- Pull and inspect the anode rod; replace it if it's eaten down to the core wire
- Test the relief valve and check the expansion tank's air charge
- Check the burner and venting on gas units, or the elements on electric
- Descale tankless heat exchangers with a pump and solution

How often?
For tanks, once a year is a good habit in Rio Rancho. Tankless units should be descaled yearly, or more often in larger households. Homes with a working softener can stretch it.
Softeners and scale filters
A whole-house softener protects the water heater along with faucets, dishwashers and glass. A smaller scale-inhibitor cartridge just ahead of a tankless unit is a lower-cost middle ground. See hard water and your water heater.

Common questions
Can flushing fix a noisy tank?
Often it quiets it. If the scale has hardened for years, the noise may not fully go away.
What is an anode rod?
A sacrificial metal rod that corrodes so the tank doesn't. Replacing it before it's gone extends tank life.